095161

M-Bus to IP interface converter, MPW60/IP

BESD offers a wide range of M-Bus to IP interface converters for 60 devices with an M-Bus interface. There are various converters with an Ethernet to M-Bus interface. The modules, suitable for DIN-rail mounting, can be supplied with 24V AC/DC or 230V AC.

Read more

Product variants

Article Number Product Name
095161 + BIALON MPW-60/IP 230Vac + Request quote
M-Bus level converter for 60 M-Bus devices, 10/100MBaseT Ethernet interface, power supply 230VAC
095160 + BIALON MPW-60/IP 24Vac/dc + Request quote
M-Bus level converter for 60 M-Bus devices, 10/100MBaseT Ethernet interface, power supply 24V AC/DC

Description

The M-Bus level converter BIALON MPW-60/IP lets you connect up to 60 M-Bus endpoints with a standard load of 1.5 mA each to an M-Bus Master via an Ethernet connection. The M-Bus Master can be, e.g., a PC or an embedded controller. The level converter translates the signals from the M-Bus Master on the Ethernet interface to M-Bus signals, and vice-versa. Up to 250 MPW-60/IP can be connected to a PC-based M-Bus Master. The IP addresses on the level converter are assigned to virtual COM ports on the master. If needed, they can be grouped on the M-Bus Master via an additional program to use a single COM port. This means that an M-Bus Master program that only works with one COM port can communicate simultaneously with all M-Bus endpoints connected via the individual level converters. The level converter has overload protection and is thus short-circuit protected. The trip threshold is 110 mA. Additionally, the M-Bus interface has overvoltage protection on the bus side. The LEDs indicate the major operational and  malfunction states, such as power supply, send or receive data, and bus overload. The M-Bus BIALON MPW-60/IP level converter is available in two variants with a 230 V AC or 24 V AC/DC power supply.

Specifications

M-Bus end points:
60 (standard load: 1.5 mA)
Supply voltage:
110 V to 250 V AC or 20 V to 28 V AC/DC
M-Bus voltage:
36 V - 42 V
max. M-Bus idle current:
90 mA (60 standard loads)
Over cuurent threshold:
<110 mA
Electrical isolation:
between the power supply, Ethernet and M-Bus
Ethernet:
10/100BaseT
Transfer rate:
M-Bus 300 … 9600 baud
LED indication:
  • LED green: power on
  • LED yellow: Transmit M-Bus
  • LED green: Receive M-Bus
  • LED red: Bus Overload
  • LED green: PKD (Packet Detect –> IP port)
  • LED yellow: LNK (Link Status –> IP port)
M-Bus endpoints:
60 (standard load: 1.5 mA)

Do you have a request?

Request type
Art. Nr. Product name Remove

You can add another variation to your request

Do you have a request?