ZigBee S0 optische inaterface voor energiemeter, ZR-TIDCI-OPT1-EM
ZigBee S0 optische interface voor energiemeters.
Product varianten
Artikelnummer | Productnaam | |
---|---|---|
0414-ZR-TIDCI-OPT1-EM + | ZR-TIDCI-OPT1-EM | + Vraag offerte aan |
ZigBee S0 optische interface energiemeter |
Beschrijving
The ZR-TIDCI-OPT1-EM counts, stores and transmits to a Gateway optical pulses generated by a counter ENEL, which correspond to a certain energy measured by the latter. The energy per pulse is set from 1 to 99 Wh. It is also supplied with a generic digital input that can be used to transfer a state of alarm coming from outside (with contact). The internal energy meter with resolution in Wh can be reset or set to a desired value to synchronize with the ENEL energy meter. The counts are transmitted on a regular basis and to a programmable Gateway. The device must be continuously powered to 12-24 Vdc / Vac (power supply included); it can also act as a repeater and or a parent device for battery-powered sensors.
Key features:
- LED pulse counter of electricity and energy meter settable from 1 to 99 Wh/pulse
- It manages electricity and energy meter in Wh
- Digital input for remote alarms
- Compatible with ENEL energy meter (single phase/three phase); other European energy meters under development
Specificaties
- General specifications:
-
- Chip Ember EM250
- Compatible IEEE 802.15.4
- Stack EmberZnet 3.5.x (ZigBee PRO)
- Modbus/RTU
- Device address settable via internal dip-switch
- Wall mounting with screws Cable gland: PG9
- RF characteristics:
-
- Frequency: 2405 MHz ÷ 2480 MHz
- Modulation: DSSS
- Nominal transmission power: 10mW (10 dBm)
- Receiver sensitivity: -97 dBm
- External antenna gain: 5,5 dB
- Range outdoor/indoor: 200m/50m
- Power supply:
- 12-24 Vdc/Vac; 100mA; 50/60Hz Power supply included 230 Vac (±20%); 50/60Hz
- Digital input:
-
- Electronic type not insulated inputs for clean contact
- Short circuit current 0,01mA. Use self-cleaning contacts.
- Connections:
- Pull out terminals (3,81 mm pitch)
- Environment parameters:
-
- Operating temperature: -10 ÷ +60°C; <80% U.R. not condensing
- Storage temperature: -20 ÷ +70°C; <80% U.R. not condensing
- Degree of protection: IP 55
- Conformity:
-
- Community Directives 2006/95/EEC, 89/336/EEC, 99/5/EEC
- ETSI-EN 300 328; ETSI EN301 489; EN 50371
- EN60950-1; EN61000-6-2; EN61000-6-3
- Immunity; EN 60950-1: Electric Safety