CAN-bus to Single mode converter, DL-CAN-2x
The DL-CAN-2x modules connect CAN field bus networks (e.g. CAN, CANopen, DeviceNet) via single mode fiber optics. With the help of this innovative system, optical bus, star, tree and mixed structures are possible. These modules are equiped with FiberView. The "traffic light" LEDs gives you an indication of the quality of the fiber optic link.
Product variants
Article Number | Product Name | |
---|---|---|
010007481-L-FV + | DL-CAN/2x13-SM-ST CAN/SM/Line/Star/FiberView | + Request quote |
CAN-bus to Single mode converter for a line, star or tree network, ST adapter. | ||
010007483-L-FV + | DL-CAN/2x13-SM-SC CAN/SM/Line/Star/FiberView | + Request quote |
CAN-bus to Single mode converter for a line, star or tree network, SC adapter. | ||
010007483-BIDI + | DL-CAN/2x13-SM-SC-BIDI CAN/SM/Line/Star | + Request quote |
CAN-bus to Single mode BIDI converter for a line, star or tree network, SC adapter. | ||
010007485 + | DL-CAN/2x13-SM-E2000 CAN/SM/PzP/FiberView | + Request quote |
CAN-bus to Single mode converter for a line, star or tree network, E2000 adapter. |
Description
The DL CAN systems connect CAN field bus networks (e.g. CAN, CANopen, DeviceNet) via fiber optics. With the help of this innovative system, optical bus, star, tree and mixed structures are possible.
LEDs and potential-free contacts of a fault detector relay are able to signal defective states.
FiberView works similarly to a traffic light. If the “traffic light” is green, everything is fine. If the yellow LED lights, the budget is still tolerable, but already below a certain system reserve. Additionally to the LED, this pre-warning level is also signaled by a potential-free contact. If the “traffic light” turns red there is a serious error.
Specifications
- FO-connector:
- ST, SC, E2000 or SC-BIDI
- Fiber type:
- Singlemode 9/125µm
- Optical budget:
- 16 dB
- FO range:
- 30 km, others up to 100 km on request (0,3 dB/km)
- Wavelength:
- 1310 nm (1310/1550 nm for BIDI version)
- Data rate:
- 10, 20, 22,2, 50, 100, 125, 250, 500, 800, 1000 KBaud Switchable: none or wave impedance (Rw + Rpd + Rpu)
- Transmission type:
- Half duplex
- Indentifier:
- 11 Bit, 29 Bit or both
- Terminating resistor:
- Switchable: none or wave impedance (Rw + Rpd + Rpu)
- CAN cable length:
- Acc. to CAN Specification
- CAN connector:
- 9-pole Sub-D female and 6-pole terminal
- Status LEDs:
- Power supply (green) / Failure (red) / Data receive (green) / Status (red) / FiberView (red, yellow, green)
- Power supply:
- 12 to 30 VDC, other voltages on request
- Power consumption:
- 5 Watts, 200 mA (24 V)
- Galvanic isolation:
- 500 VDC (24 VDC <> CAN)
- Operating temperature:
- -40°C to +70°C (Multimode and Singlemode with ST or SC) / -20°C to +55°C (all others)
- EMC:
- EN61000-6-2/EN55022 Class B + A1 + A2
- Weight:
- 570 g
- Dimensions:
- 60 x 100 x 113 mm (60 x 120 x 113 mm incl. connector)
- Housing:
- Stainless steel, powder coated